Heat pump, System
The scheme provides data for a potential heat pump contributing to space heating. Data are determined according to relevant European standards.
- Type: In this field it is selected whether the heat pump is solely for production of domestic hot water (dhw) or can produce both hot water and heating. Alternatively, it can be a duo solution with one heat pump for domestic hot water and one for space heating. NB: Systems for production of domestic hot water are currently inactive in BSim.
Room Heating
Nom. Efficiency: The nominal power is the power delivered from the heat pump at the test conditions as stated below. For heat pumps for dhw the nominal power is not necessarily determined in the test. In these cases the average annual power for heating dhw can be used instead.
Nom. COP: The nominal COP is the efficiency of the heat pump at the given test temperatures. The COP is given including eventual supporting equipment if it is part of the test. Additional supporting equipment, which is not part of the COP determined during the test must be given separately.
Rel. COP 50 % load: The relative COP at 50 % load of the heat pump is the COP at 50 % load divided by the COP at 100 % load. The relative COP at 50 % load of the heat pump is determined according to CEN TS 14825. If the relative load is not determined according to CEN TS 14825, a value of 0.80 is assumed. The parameter is not relevant for heat pumps for dhw.
Test: In the section are given the test-temperatures, which have been used in the determination of the load and the efficiency of the heat pump. The test-temperature at the hot side must be higher or equal to the temperature at the cold side.
Cold side
Test Temp.: Test-temperature at the cold side is the temperature of the media at the evaporator.
Source: This section defines the media on the cold side of the heat pump, i.e. which source and which media the heat is delivered to at the hot side. The media is selected in the combo box.
Cold side: At the cold side it is possible to select among:
Ground buried pipes,
Exhaust, and
Ambient air.
Warm side
Test temp.: The test-temperature at the warm side is the temperature of the media next to the condenser.
For heat pumps for combined production of space heating and dhw, and where it is documented that heating of dhw primarily happens by exploiting excess room temperatures, a test-temperature of 50 °C at the warm side in combination with the actual test values for space heating can be used. These values can be used if no test of the heat pump can be undertaken for production of dhw according to acknowledged international standards.Source: At the warm side it is possible to choose between:
Room air,
Inlet air, and
Hydronic heating system.
Before simulating a heat pump it is necessary to define the design parameters for the heat pump. This is done in SimView by right-clicking in the graphic representation of the model and from the menu selecting Defaults. Jump to the tab Heatloss, and click OK.
The heat pump cannot be activated as a source for the heating system until the external program PackCalc has been installed. PackCalc has been developed by IPU Technology development at Danish Technical University (DTU).
Domestic hot water
The functions for calculation of production of domestic hot water is currently inactive in BSim.
See also: